{"product_id":"apc-apdu9953-power-distribution-unit-pdu-24-ac-outlets-0u-black","title":"APC APDU9953 power distribution unit (PDU) 24 AC outlet(s) 0U Black","description":"\u003cstyle\u003etable.generic tr th {background: #eee;}\u003c\/style\u003eRack PDU 9000 Switched, ZeroU, 32A, 230V, (21) C13 \u0026amp; (3) C19\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWith Industry leading reliability, manageability, and security, APC Switched Rack PDU's provide advanced load management plus on\/off outlet level power cycling and sequencing control\u003c\/li\u003e\n\u003cli\u003eIncludes: Installation guide, Rack mounting brackets, Safety guide, Serial configuration cable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDescription\u003c\/h2\u003e\u003cb\u003eNetShelter Switched Rack PDUs Features \u0026amp; Benefits\u003cbr\u003eManageability\u003c\/b\u003e\u003cbr\u003e1% Metering Accuracy\u003cbr\u003eProviding the same level of accuracy as a utility company meter by adhering to IEC 62053-21 class 1, 1% metering accuracy provides peace of mind to use these PDUs to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Available on 9000 series PDUs.\u003cbr\u003eGigabit Ethernet Connectivity\u003cbr\u003e9000 series PDUs provide Gigabit Ethernet to enhance and standardize network connectivity across all assets in the data center. All other models provide 10\/100 ethernet connectivity.\u003cbr\u003eNetwork Port Sharing\u003cbr\u003eConnect and manage multiple PDUs from one IP address to simplify and speed deployment while saving the cost required in having a dedicated network connection for each PDU. Manage up to 32 PDUs with 9000 series and up to 4 PDUs with 8000 series.\u003cbr\u003eMulti-tier user access\u003cbr\u003eSupports up to four access levels - Administrator, Device User, Read-Only User and Network-only User - with user name and password requirements.\u003cbr\u003eOutlet Level Grouping\u003cbr\u003eOutlet power sequencing can be configured to group any combination of outlets to power up or down together providing flexibility.\u003cbr\u003eEcoStruxure IT Ready\u003cbr\u003eSeamless integration of one or many PDUs including alerts and control with EcoStruxure IT. Allows IT and data center professionals to monitor and manage all of their critical IT infrastructure on-premise, in the cloud, and at the edge from anywhere.\u003cbr\u003eEnhanced Cybersecurity\u003cbr\u003e9000 series PDUs include APC Network Management card with security features including secured interfaces and a modified password policy providing peace of mind.\u003cbr\u003eNetwork Management Capabilities\u003cbr\u003eFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.\u003cbr\u003eAlarm Thresholds\u003cbr\u003eDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.\u003cbr\u003eAlarm Thresholds\u003cbr\u003eDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAdaptability\u003c\/b\u003e\u003cbr\u003eRack-Mountable\u003cbr\u003eIncludes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.\u003cbr\u003eSingle input power source\u003cbr\u003eSupply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.\u003cbr\u003eWide range of input and output connections\u003cbr\u003eProduct family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 17.3kW using a single branch whip.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAgility\u003c\/b\u003e\u003cbr\u003eWireless Connectivity\u003cbr\u003eCompatible with the optional APC USB WiFi Device for cableless connectivity over WiFi that speeds deployment and simplifies moves, adds, and changes (9000 Series PDUs only - expected to be available on units manufactured after March 2021).\u003cbr\u003eFlash Upgradeable\u003cbr\u003eQuickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAvailability\u003c\/b\u003e\u003cbr\u003e60C Operating Temperature\u003cbr\u003eSelect 9000 series PDUs provide the ability to operate in a maximum ambient air temperature of 60C (140F) at full load ensuring reliability and availability even in today's high density deployments. Other models allow up to 45C (113F).\u003cbr\u003eHydraulic Magnetic Circuit Breakers\u003cbr\u003eProvide increased availability by maintaining trip current over a wide temperature range.\u003cbr\u003eC13\/C15 and C19\/C21 Hybrid Outlets\u003cbr\u003eAvailable on select 9000 series PDUs only, Industry 1st hybrid outlets allow 60C operating temperature at full load, are fully compatible with standard C14 and C20 power cords, and are future proofed for implementation of higher temperature rated devices requiring C16 and C21 power cords.\u003cbr\u003eHigh Retention Outlets\u003cbr\u003eWith no special power cords required, high retention outlets provide up to twice the holding force to reduce risk of accidental disconnect on 9000 series PDUs.\u003cbr\u003eField-replaceable NMC\u003cbr\u003eIntegrated Network Management Card\/Display Module can be replaced in the field to minimize downtime disruption in the unlikely event of a failure.\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"generic\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eDesign\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn\/off switch\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePDU types\u003c\/td\u003e\n\u003ctd\u003eSwitched\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct colour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eEAC, EN 55022 class A, EN 55024, EN 61000-3-2, EN 61000-3-3, RCM, VDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack capacity\u003c\/td\u003e\n\u003ctd\u003e0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePorts \u0026amp; interfaces\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC outlets quantity\u003c\/td\u003e\n\u003ctd\u003e24 AC outlet(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC outlet types\u003c\/td\u003e\n\u003ctd\u003eC13 coupler, C19 coupler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower plug\u003c\/td\u003e\n\u003ctd\u003eIEC 60309\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eFeatures\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eEAC, EN 55022 class A, EN 55024, EN 61000-3-2, EN 61000-3-3, RCM, VDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePower\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum power\u003c\/td\u003e\n\u003ctd\u003e7360 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal input voltage\u003c\/td\u003e\n\u003ctd\u003e200, 208, 230, 220-240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum current\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad capacity\u003c\/td\u003e\n\u003ctd\u003e7400 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC input frequency\u003c\/td\u003e\n\u003ctd\u003e50 - 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eWeight \u0026amp; dimensions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e56 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e46 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e1829 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage width\u003c\/td\u003e\n\u003ctd\u003e165 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage depth\u003c\/td\u003e\n\u003ctd\u003e124 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage height\u003c\/td\u003e\n\u003ctd\u003e2040 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage weight\u003c\/td\u003e\n\u003ctd\u003e9.95 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePackaging data\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage width\u003c\/td\u003e\n\u003ctd\u003e165 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage depth\u003c\/td\u003e\n\u003ctd\u003e124 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage height\u003c\/td\u003e\n\u003ctd\u003e2040 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage weight\u003c\/td\u003e\n\u003ctd\u003e9.95 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eOperational conditions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e-5 - 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e-25 - 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e5 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e0 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003e0 - 3048 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating altitude\u003c\/td\u003e\n\u003ctd\u003e0 - 15240 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"APC","offers":[{"title":"Default Title","offer_id":57012773683545,"sku":"APDU9953","price":1580.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0882\/5874\/0569\/files\/nukwpDr9BUmaJ085vX0N-Q.c-m.jpg?v=1769064576","url":"https:\/\/an-electronics.com\/products\/apc-apdu9953-power-distribution-unit-pdu-24-ac-outlets-0u-black","provider":"AN Electronics","version":"1.0","type":"link"}